Status¶
Page presenting data read from the device, such as the state of outputs, PWM outputs, analog inputs, digital inputs, sensor readings and proper names for all of the listed fields.
Elements of page¶
- Top navigation bar, visible on every page after logging in. On the left, it contains information about the firmware and hardware versions, a green padlock for https connection, and a link to the documentation page for the currently displayed page. On the right there is a link to UI settings, help materials and a logout button.
-
Information panel.
- time since the last restart (Uptime)
- date and time of the device
- firmware and hardware version
- power supply voltage
- temperature and humidity readings from the on-board sensor
Option confirmation that the device was on or after restart
After power on or restart, the Uptime field has a red background. If you click on this field, it will change to orange and remain like that until the device is restarted.
Thanks to this you can check whether in the meantime the device has been restarted or lost power, without having to remember the value of Uptime - just check on the website if the highlight color has changed.
-
Button to activate the edit mode of the visibility of elements and to save the visibility settings.
-
Outputs ON/OFF.
It contains fields with an editable name and a change state button that also shows the current state. There is also information on the buttons whether the periodic switching is on - the inscription AUTO appears.
-
PWM outputs.
It contains a field with an editable name, a state change button, and a slider to change the fill factor.
-
Buttons for setting the state of special VAR variables.
-
Analog sensors.
It contains a field with an editable name and a converted value from the selected sensor (eg value of the current).
-
Temperature, humidity and pressure measurements.
Fields with an editable name and fields with reading.
Selection of active sensors in the I2C and 1-Wire sensors tab.
-
Other measurements (CO2 and PM).
It contains a field with an editable name and a field with a reading.
Selection of active sensors in the Serial port and I2C and 1-Wire sensors tabs.
-
Mapped readings (Modbus or custom 1-Wire measurements) - fields with name, value and unit.
-
Differential measurements.
Displays the difference, sum, quotient or product of two selected measurements (e.g. temperature, power, energy). Configurable in the Inputs tab.
-
Digital inputs.
Fields with an editable name and fields with the current state.
-
Power and energy readings.
It contains a field with an editable name and fields with power and energy readings.
Editable names
Name must have from 1 to 15 characters, excluding %
, &
, *
, #
, "
.
Visibility of elements¶
The user can choose which fields should be visible on the Status and Status for user pages. To do this, click the button Configure the visibility of elements in the upper right part of the page.