Remote control¶
/stm.cgi?remote¶
Configure the remote control settings.
GET /stm.cgi?remote=A*B*C*D*E*F*G*H*I*J*K*L*M*N*O*P*Q
A
determines whether the function is enabled, integer0-1
B
determines which fields are selected for Active_low, integer0-4095
(12 bits sequentially for INPD1-INPD4, EVENT1-EVENT8)C
is the host of controlled LC, stringD
is a port for communication with another LC, integerE
is the password, stringF
determines which outputs will be driven upon INPD1 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)G
determines which outputs will be driven upon INPD2 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)H
determines which outputs will be driven upon INPD3 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)I
determines which outputs will be driven upon INPD4 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)J
determines which outputs will be driven upon EVENT1 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)K
determines which outputs will be driven upon EVENT2 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)L
determines which outputs will be driven upon EVENT3 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)M
determines which outputs will be driven upon EVENT4 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)N
determines which outputs will be driven upon EVENT5 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)O
determines which outputs will be driven upon EVENT6 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)P
determines which outputs will be driven upon EVENT7 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)Q
determines which outputs will be driven upon EVENT8 changes, integer0-262143
(18 bits sequentially for OUT0-OUT5, PWM0-PWM3, EVENT1-EVENT8)
Example:
http://192.168.1.100/stm.cgi?remote=0*15*ip.com*30000*password*0*0*0*0*0*0*0*0*0*0*0*0